INSPEÇÃO TERMOGRÁFICA DE FACHADAS – INVESTIGAÇÃO DA INFLUÊNCIA DA FISSURAÇÃO

Autores/as

  • E. Bauer Universidade de Brasília, PECC Autor/a
  • E. Pavón Universidade de Brasília, PECC Autor/a
  • E. Oliveira Universidade de Brasília, PECC Autor/a

Palabras clave:

termografia, fachada, fissura, Infrared thermography is an evaluation technique that helps to identify anomalies and can provide information on the incidence and severity, The aim of this study is to apply quantitative thermography to study a case of severe cracks in facade analyzing the evolution of temperatures and Delta-T. There was the study of the evolution of temperature over a day, occurring incidence of the sun part of the day which allows you to calculate and assess the evolution of the associated temperatures, It done the acquisition of thermograms hourly of the study period, It is observed that the highest temperatures occur at 12:00 hours and the larger Delta-T between 10:00 and 12:00, There were differences between the Delta-T's profile among the three regions studied, The best time for analysis is that it has greater Delta-T. Cracks with higher Delta-T were considered more degraded, and that branched generalized cracks did not allow comparative conclusion

Resumen

A termografia de infravermelho é uma técnica não destrutiva de inspeção, que auxilia na identificação das anomalias e pode fornecer informações sobre a extensão e gravidade das mesmas. O objetivo do presente estudo é aplicar a termografia quantitativa ao estudo de um caso de fissuração intensa em fachada revestida em argamassa, analisando a evolução das temperaturas e do Delta-T. Faz-se o estudo da evolução das temperaturas ao longo de um dia de análise, ocorrendo incidência do sol em parte do período de estudo, o que permite calcular e avaliar a evolução das temperaturas associadas. É efetuada a aquisição de termogramas a cada hora do período estudado. Pela evolução dos parâmetros, observa-se que as maiores temperaturas ocorrem as 12:00 horas, e os maiores Delta-T entre 10:00 e 12:00 horas. Houve diferença entre o perfil do Delta-T entre as 3 regiões estudadas. O melhor momento para análise é o em que se tem maiores Delta-T. Fissuras com maiores Delta-T foram consideradas mais degradadas, sendo que as fissuras ramificadas não permitiram conclusão comparativa

Referencias

Barreira, E,; de Freitas, V.P." Evaluation of building materials using infrared thermography". Constr Build Mater 2007;21:218–224.

Bauer, E.; Castro, E.K.; Hildenberg, A.; Pavon, E. "Critérios para a aplicaçao da termografia de infravermelho passiva como tecnica auxiliar ao diagnóstico de patologias em fachadas de edifícios". Rev Politec (Instituto Politécnica da Bahia) 2014;26:266–277.

Maldague X. Theory and Practice of Infrared Technology for Nondestructive Testing. Wiley. NY, USA: 2001.

Paoletti, D.; Ambrosini, D. Sfarra, S.; Bisegna, F. "Preventive thermographic diagnosis of historical buildings for consolidation". J Cult Herit 2013;14:116–121.

Bauer, E.; de Freitas, V.P.; Mustelier, N.; Barreira, E. "Infrared thermography – evaluation of the results reproducibility". Struct Surv 2015;31:181–193.

De Freitas, S.S.; de Freitas, V.P.; Barreira, E. "Detection of façade plaster detachments using infrared thermography – A nondestructive technique". Constr Build Mater 2014;70:80–87.

Edis,E,.;Flores-Colen, I.; de Brito, J. "Passive thermographic detection of moisture problems in façades with adhered ceramic cladding". Constr Build Mater 2014;51:187–197.

ASTM E1862-97 (2010). Standard Test Methods for Measuring and Compensating for Reflected Temperature Using Infrared Imaging Radiometers. vol. 97. West Conshohocken, Pennsylvania, United States: 2010.

ASTM 1933-99. Standard Test Methods for Measuring and Compensating for Emissivity Using Infrared. West Conshohocken, Pennsylvania, United States: 1999.

Bauer E, Castro EK, Pavon E, Oliveira AHS. "Criteria for application and identification of anomalies on the facades of buildings with the use of passive infrared thermography". In: Freitas VP, editor. 1st Int. Symp. Build. Pathol., Porto, Portugal: 2015.

Bauer E, Pavón E. "Termografia de infravermelho na identificação e avaliação de manifestações patológicas em edifícios". Concreto & Construções 2015:93–98.

Vavilov V. "Noise-limited thermal/infrared nondestructive testing". NDT E Int 2014;61:16–23.

Publicado

2016-04-18

Cómo citar

Bauer, E., Pavón, E., & Oliveira, E. (2016). INSPEÇÃO TERMOGRÁFICA DE FACHADAS – INVESTIGAÇÃO DA INFLUÊNCIA DA FISSURAÇÃO. CONGRESSO BRASILEIRO DE PATOLOGIA DAS CONSTRUÇÕES (CBPAT), 2, 1433-1441. https://anais.cbpat.org.br/cbpat/article/view/405

Artículos más leídos del mismo autor/a

Artículos similares

1-10 de 50

También puede Iniciar una búsqueda de similitud avanzada para este artículo.