THERMOMECHANICAL RESPONSE OF RC BEAMS UNDER EV FIRE EXPOSURE
A NON-COUPLED CFD–FEA INVESTIGATION
DOI:
https://doi.org/10.67775/w9wx9e86Palavras-chave:
vigas, concreto armado, estruturas ao incêndio, veículos elétricosResumo
This study evaluates the thermomechanical response of reinforced concrete (RC) beams subjected to Electric Vehicles (EV) fire scenarios, which impose more severe thermal loads than the ISO 834 curve adopted in EN 1992-1-2. A coupled thermal–mechanical finite element analysis (FEA) was conducted on nine beams, varying reinforcement layout, diameter, and concrete cover thickness. Compared with code-based predictions, EV fires reduced fire resistance by up to 27% within 60 min. Increasing concrete cover (≥30 mm) and using multiple reinforcement layers improved performance by limiting steel stresses. Results suggest current provisions may underestimate EV fire, indicating the need to update fire resistance criteria and detailing rules for RC structures.
Downloads
Publicado
Edição
Seção
Licença
Direitos autorais (c) 2026 Fabricio Bolina, Débora Bretas Silva, Eduardo Pachla (Autor)

Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.